Default Re: SSA adapter replacement in HACMP enviroment

LABEL ALL CABLES!!!!!

How many VG's involved?
if just the one just
>move the resources to the other HA box
>stop the cluster services on the system with the bad SSA adapters
>shutdown and replace the adapters
>fire it back up... if the cables are all in the original places, then the pdisk hdisk mapping should come out the same.


you really don't need to remove all that stuff... if the pdisk/hdisks
do get all screwed up then rmdev them and cfgmgr... they should come
back in with PVID's as well as the associated VG's...

fire up the cluster services and failback the stuff you want on this
system...
hope it helps