Hellor Aranaud,
FIEFFE Arnaud wrote:
> Hello,
>
> Does anyone have any experience in using AIX 5.2 Multi-path I/O
> instead of EMC˛ PowerPath with an EMC˛ Symmetrix with an FC SAN ?
Don't take it as 100% true from me, but from what
I know the PowePath option is only to provide multipath
feature in AIX 4.3.3 (and maybe older).
Please read the "Release Notes" for AIX 5.2 to know
limitations and/or new features for multi-path.
>
> Regards,
>
> Arnaud FIEFFE
kind regards,
--
Claudiu Costin,
claudiuc@kde.org
Linux-KDE Romania
http://www.ro.kde.org